{"product_id":"graco-te80-0085-quantm-i80-15-npt-aluminum-electric-diaphragm-pump-200-240-v-al-center-ss-seat-sp-ball-sp-diaphragm","title":"Graco | TE80-0085 QUANTM i80, 1.5\"NPT, Aluminum Electric Diaphragm Pump, 200-240 V, AL Center, SS Seat, SP Ball, SP Diaphragm","description":"\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eGraco\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eModel: TE80-0085\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe QUANTM electric pump offers a significant advancement in pump technology. Its innovative electric motor design reduces operational costs and ensures consistent production line operation. With various fluid path material options, QUANTM is suitable for most fluid applications. It serves as a reliable replacement for less efficient pneumatic pumps or as a component in new installations. The pump features a unique self-priming, seal-less design that provides smooth, steady flow. It is the only electric diaphragm pump on the market that stalls under pressure, minimizing downtime caused by clogged lines or closed valves. The QUANTM is engineered for quieter operation, increased efficiency, and enhanced dependability, contributing to energy savings and sustainability goals. Consider upgrading your pump strategy to a QUANTM electric pump to improve your bottom line.\u003c\/p\u003e\n\u003cp\u003eThe all-aluminum fluid section is designed for abrasion resistance and mild corrosion resistance. This general-purpose electric pump provides up to 8x more continuous torque at low speeds than conventional motors, making it an energy-efficient solution for sump evacuation, petroleum product evacuation (new and waste oils), and solvent evacuation. This pump enhances reliability to reduce downtime and features a plug-and-play design for easy integration into existing production lines without additional investment or infrastructure changes. Not suitable for use with halogenated hydrocarbons.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevolutionary Design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eReplace existing air-operated pumps with electric pump technology that stalls under pressure and includes the AutoPrime feature.\u003c\/li\u003e\n\u003cli\u003eA compact and efficient electric drive eliminates the gearbox, resulting in a footprint comparable to a pneumatic diaphragm pump.\u003c\/li\u003e\n\u003cli\u003eAchieve up to 80% reduction in energy consumption compared to pneumatic pumps, lowering operating costs and offering a rapid investment payback.\u003c\/li\u003e\n\u003cli\u003eQuiet operation reduces plant noise levels, improving employee safety and health.\u003c\/li\u003e\n\u003cli\u003eSmart pump control enables more precise flow set points and includes built-in I\/O capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Electric Motor\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePowder-coated aluminum electric drive.\u003c\/li\u003e\n\u003cli\u003e240 VAC 1Ph motor with a 15 ft cord and IEC 60320-C20 plug.\u003c\/li\u003e\n\u003cli\u003eNon-hazardous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials of Construction\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAluminum fluid section with NPT end port.\u003c\/li\u003e\n\u003cli\u003eInternal components include a 316 stainless steel seat, Santoprene ball, Santoprene diaphragm, and PTFE manifold o-ring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e\n  .spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n    font-size: 15px;\n    box-shadow: 0 4px 12px rgba(0, 0, 0, 0.05);\n    border-radius: 8px; \/* Slightly rounded corners for a modern feel *\/\n    overflow: hidden; \/* Ensures border-radius clips the table *\/\n  }\n\n  .spec-table th,\n  .spec-table td {\n    padding: 14px 18px;\n    text-align: left;\n    border-bottom: 1px solid #eaeaea;\n  }\n\n  \/* Table Header *\/\n  .spec-table th {\n    background-color: #f9f9f9;\n    font-weight: 600;\n    letter-spacing: 0.5px;\n    color: #333;\n  }\n\n  \/* Table Body *\/\n  .spec-table tbody tr {\n    background-color: #ffffff;\n  }\n\n  \/* Zebra-striping for readability *\/\n  .spec-table tbody tr:nth-of-type(even) {\n    background-color: #fdfdfd;\n  }\n\n  \/* Subtle hover effect *\/\n  .spec-table tbody tr:hover {\n    background-color: #f5f5f5;\n  }\n\n  \/* Style the attribute name (first column) *\/\n  .spec-table td:first-child {\n    font-weight: 500;\n    color: #222;\n    width: 40%; \/* Give the label column a consistent width *\/\n  }\n\n  \/* Style the value (second column) *\/\n  .spec-table td:last-child {\n    color: #555;\n  }\n\n  \/* Remove bottom border from the last row for a cleaner look *\/\n  .spec-table tbody tr:last-child td {\n    border-bottom: none;\n  }\n\u003c\/style\u003e\n\n\n\u003ch4\u003eOperational Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUPC Product\u003c\/td\u003e\n      \u003ctd\u003e769946686692\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDivision\u003c\/td\u003e\n      \u003ctd\u003ePRO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeight\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLength\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWidth\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVolume\u003c\/td\u003e\n      \u003ctd\u003e0 FT3 | 0.000 M3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e0 LBS | 0.000 KG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e38.1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e38.1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Amperage (A)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Flow Rate (L\/min)\u003c\/td\u003e\n      \u003ctd\u003e303\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (bar)\u003c\/td\u003e\n      \u003ctd\u003e6.9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (kPa)\u003c\/td\u003e\n      \u003ctd\u003e690\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (psi)\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (in)\u003c\/td\u003e\n      \u003ctd\u003e0.19\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e4.8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eQUANTM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Height (in)\u003c\/td\u003e\n      \u003ctd\u003e19.6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003ei80\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e104\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e82\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e180\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Section\u003c\/td\u003e\n      \u003ctd\u003eAluminum, End Port, NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (m)\u003c\/td\u003e\n      \u003ctd\u003e4.57\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (ft)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e38\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003econfiguration_code\u003c\/td\u003e\n      \u003ctd\u003eQTD-ALFC2SSSPSPPTA100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Graco","offers":[{"title":"Default Title","offer_id":48980985610548,"sku":"TE80-0085","price":5221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1483\/4824\/files\/Graco-TE80-0085_73424f74-063c-4030-b570-f1c1639af2a9.jpg?v=1766174499","url":"https:\/\/hydrotechnologysystems.supply\/products\/graco-te80-0085-quantm-i80-15-npt-aluminum-electric-diaphragm-pump-200-240-v-al-center-ss-seat-sp-ball-sp-diaphragm","provider":"HTS Supply LLC","version":"1.0","type":"link"}