{"product_id":"graco-te30-1041-quantm-i30-1-npt-aluminum-electric-diaphragm-pump-380-480-vac-3ph-al-center-fk-seat-fk-ball-fk-diaphragm","title":"Graco | TE30-1041 QUANTM i30, 1\"NPT, Aluminum Electric Diaphragm Pump, 380-480 VAC 3Ph, AL Center, FK Seat, FK Ball, FK Diaphragm","description":"\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eGraco\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eModel: TE30-1041\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe QUANTM electric pump offers a significant advancement over traditional electric pumps. Its innovative electric motor design reduces operational costs and ensures production line reliability. With various fluid path options and materials, QUANTM is suitable for most fluid applications, serving as a dependable replacement for less efficient pneumatic pumps or for new installations. Its unique self-priming, seal-less design provides consistent flow. It is the only electric diaphragm pump on the market that stalls under pressure, minimizing downtime from clogged lines or closed valves. The QUANTM is engineered for quieter, more efficient, and highly dependable operation, delivering energy savings that support sustainability goals. Consider upgrading your pump strategy with a QUANTM electric pump to improve your bottom line.\u003c\/p\u003e\n\u003cp\u003eThe all-aluminum fluid section is designed for abrasion resistance and compatibility with mild chemicals. This general-purpose electric pump features an energy-saving motor with up to 8 times more continuous torque at low speeds than conventional motors. It is ideal for sump evacuation, as well as for handling petroleum products (new and waste oils) and solvents. This pump offers high reliability to reduce downtime, and its plug-and-play design allows for easy integration into existing production lines without major investment or infrastructure changes.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevolutionary Design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eReplace existing air-operated pumps with electric pump technology that stalls under pressure and includes the AutoPrime feature.\u003c\/li\u003e\n\u003cli\u003eA compact and efficient electric drive eliminates the gearbox, resulting in a footprint comparable to a pneumatic diaphragm pump.\u003c\/li\u003e\n\u003cli\u003eAchieve up to an 80% reduction in energy consumption compared to pneumatic pumps, lowering operating costs and providing a rapid return on investment.\u003c\/li\u003e\n\u003cli\u003eQuiet operation contributes to a reduction in plant noise levels, enhancing employee safety and well-being.\u003c\/li\u003e\n\u003cli\u003eSmart pump control offers more precise flow set points and integrated I\/O capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Electric Motor\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePowder-coated aluminum electric drive.\u003c\/li\u003e\n\u003cli\u003e380-480 VAC 3Ph motor with 15 ft flying leads.\u003c\/li\u003e\n\u003cli\u003eClass 1, Division 1 hazardous location approval.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials of Construction\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAluminum fluid section with NPT End Port.\u003c\/li\u003e\n\u003cli\u003eInternal components include FKM (Viton) seats, FKM (Viton) balls, and FKM (Viton) diaphragms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e\n  .spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n    font-size: 15px;\n    box-shadow: 0 4px 12px rgba(0, 0, 0, 0.05);\n    border-radius: 8px; \/* Slightly rounded corners for a modern feel *\/\n    overflow: hidden; \/* Ensures border-radius clips the table *\/\n  }\n\n  .spec-table th,\n  .spec-table td {\n    padding: 14px 18px;\n    text-align: left;\n    border-bottom: 1px solid #eaeaea;\n  }\n\n  \/* Table Header *\/\n  .spec-table th {\n    background-color: #f9f9f9;\n    font-weight: 600;\n    letter-spacing: 0.5px;\n    color: #333;\n  }\n\n  \/* Table Body *\/\n  .spec-table tbody tr {\n    background-color: #ffffff;\n  }\n\n  \/* Zebra-striping for readability *\/\n  .spec-table tbody tr:nth-of-type(even) {\n    background-color: #fdfdfd;\n  }\n\n  \/* Subtle hover effect *\/\n  .spec-table tbody tr:hover {\n    background-color: #f5f5f5;\n  }\n\n  \/* Style the attribute name (first column) *\/\n  .spec-table td:first-child {\n    font-weight: 500;\n    color: #222;\n    width: 40%; \/* Give the label column a consistent width *\/\n  }\n\n  \/* Style the value (second column) *\/\n  .spec-table td:last-child {\n    color: #555;\n  }\n\n  \/* Remove bottom border from the last row for a cleaner look *\/\n  .spec-table tbody tr:last-child td {\n    border-bottom: none;\n  }\n\u003c\/style\u003e\n\n\n\u003ch4\u003eOperational Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUPC Product\u003c\/td\u003e\n      \u003ctd\u003e769946877069\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDivision\u003c\/td\u003e\n      \u003ctd\u003ePRO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeight\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLength\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWidth\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVolume\u003c\/td\u003e\n      \u003ctd\u003e0 FT3 | 0 M3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e0 LBS | 0 KG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Amperage (A)\u003c\/td\u003e\n      \u003ctd\u003e5.3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Flow Rate (L\/min)\u003c\/td\u003e\n      \u003ctd\u003e114\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (bar)\u003c\/td\u003e\n      \u003ctd\u003e6.9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (kPa)\u003c\/td\u003e\n      \u003ctd\u003e690\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (psi)\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (in)\u003c\/td\u003e\n      \u003ctd\u003e0.125\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e3.2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eQUANTM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Height (in)\u003c\/td\u003e\n      \u003ctd\u003e15.94\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003ei30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e104\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e135\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e275\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Section\u003c\/td\u003e\n      \u003ctd\u003eAluminum, End Port, NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (m)\u003c\/td\u003e\n      \u003ctd\u003e4.57\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (ft)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003econfiguration_code\u003c\/td\u003e\n      \u003ctd\u003eQTC-ALFC9FKFKFK--A100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight (kg)\u003c\/td\u003e\n      \u003ctd\u003e28.1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Graco","offers":[{"title":"Default Title","offer_id":48980973322548,"sku":"TE30-1041","price":5290.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1483\/4824\/files\/Graco_Logo_e6b745a0-a846-4ca2-af4f-a937ffbda182.jpg?v=1766174318","url":"https:\/\/hydrotechnologysystems.supply\/products\/graco-te30-1041-quantm-i30-1-npt-aluminum-electric-diaphragm-pump-380-480-vac-3ph-al-center-fk-seat-fk-ball-fk-diaphragm","provider":"HTS Supply LLC","version":"1.0","type":"link"}