{"product_id":"graco-te30-0503-quantm-i30-1-npt-aluminum-electric-diaphragm-pump-240-vac-1ph-al-center-ss-seat-ss-ball-ge-diaphragm","title":"Graco | TE30-0503 QUANTM i30, 1\"NPT, Aluminum Electric Diaphragm Pump, 240 VAC 1Ph, AL Center, SS Seat, SS Ball, GE Diaphragm","description":"\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eGraco\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eModel: TE30-0503\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe QUANTM electric pump offers a significant advancement in pump technology, designed to reduce operational costs and ensure continuous production line operation. Its innovative electric motor design and multiple fluid path options make it suitable for most fluid applications. QUANTM serves as a reliable, high-efficiency replacement for less efficient pneumatic pumps and is also ideal for new installations. Its unique self-priming, seal-less design provides smooth, consistent flow. It is the only electric diaphragm pump on the market that stalls under pressure, preventing downtime caused by clogged lines or closed valves. The QUANTM is engineered for quieter operation, enhanced efficiency, and exceptional dependability, contributing to energy savings and improved sustainability.\u003c\/p\u003e\n\u003cp\u003eThe all-aluminum fluid section is constructed for abrasion resistance and mild corrosion resistance. This general-purpose electric pump features up to 8x more continuous torque at low speeds than conventional motors, making it an energy-efficient solution for sump evacuation, petroleum product evacuation (new and waste oils), and solvent evacuation. Its high reliability minimizes downtime, and the plug-and-play design allows for easy integration into existing production lines without additional investment or infrastructure changes. Not suitable for use with halogenated hydrocarbons.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevolutionary Design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eReplace existing air-operated pumps with electric pump technology that stalls under pressure and includes the AutoPrime feature.\u003c\/li\u003e\n\u003cli\u003eThe compact and efficient electric drive eliminates the gearbox, offering a footprint comparable to a pneumatic diaphragm pump.\u003c\/li\u003e\n\u003cli\u003eAchieve up to an 80% reduction in energy consumption compared to pneumatic pumps, lowering operating costs and providing a rapid return on investment.\u003c\/li\u003e\n\u003cli\u003eQuiet operation contributes to a reduction in plant noise, enhancing employee safety and well-being.\u003c\/li\u003e\n\u003cli\u003eSmart pump control enables more precise flow set points and includes built-in I\/O functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Electric Motor\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePowder-coated aluminum electric drive.\u003c\/li\u003e\n\u003cli\u003e240 VAC 1Ph motor with 15 ft flying leads.\u003c\/li\u003e\n\u003cli\u003eATEX Ex II 2 G EX dh IIB T4 Gb hazardous location approval.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials of Construction\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAluminum fluid section with NPT end port.\u003c\/li\u003e\n\u003cli\u003eInternal components include 316 stainless steel seat, 316 stainless steel ball, Geolast diaphragm, and PTFE manifold o-ring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e\n  .spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n    font-size: 15px;\n    box-shadow: 0 4px 12px rgba(0, 0, 0, 0.05);\n    border-radius: 8px; \/* Slightly rounded corners for a modern feel *\/\n    overflow: hidden; \/* Ensures border-radius clips the table *\/\n  }\n\n  .spec-table th,\n  .spec-table td {\n    padding: 14px 18px;\n    text-align: left;\n    border-bottom: 1px solid #eaeaea;\n  }\n\n  \/* Table Header *\/\n  .spec-table th {\n    background-color: #f9f9f9;\n    font-weight: 600;\n    letter-spacing: 0.5px;\n    color: #333;\n  }\n\n  \/* Table Body *\/\n  .spec-table tbody tr {\n    background-color: #ffffff;\n  }\n\n  \/* Zebra-striping for readability *\/\n  .spec-table tbody tr:nth-of-type(even) {\n    background-color: #fdfdfd;\n  }\n\n  \/* Subtle hover effect *\/\n  .spec-table tbody tr:hover {\n    background-color: #f5f5f5;\n  }\n\n  \/* Style the attribute name (first column) *\/\n  .spec-table td:first-child {\n    font-weight: 500;\n    color: #222;\n    width: 40%; \/* Give the label column a consistent width *\/\n  }\n\n  \/* Style the value (second column) *\/\n  .spec-table td:last-child {\n    color: #555;\n  }\n\n  \/* Remove bottom border from the last row for a cleaner look *\/\n  .spec-table tbody tr:last-child td {\n    border-bottom: none;\n  }\n\u003c\/style\u003e\n\n\n\u003ch4\u003eOperational Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUPC Product\u003c\/td\u003e\n      \u003ctd\u003e769946708790\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDivision\u003c\/td\u003e\n      \u003ctd\u003ePRO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeight\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLength\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWidth\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVolume\u003c\/td\u003e\n      \u003ctd\u003e0 FT3 | 0.000 M3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e0 LBS | 0.000 KG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Amperage (A)\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Flow Rate (L\/min)\u003c\/td\u003e\n      \u003ctd\u003e114\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (bar)\u003c\/td\u003e\n      \u003ctd\u003e6.9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (kPa)\u003c\/td\u003e\n      \u003ctd\u003e690\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (psi)\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (in)\u003c\/td\u003e\n      \u003ctd\u003e0.125\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e3.2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eQUANTM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Height (in)\u003c\/td\u003e\n      \u003ctd\u003e15.94\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003ei30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e104\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e82\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e180\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Section\u003c\/td\u003e\n      \u003ctd\u003eAluminum, End Port, NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (m)\u003c\/td\u003e\n      \u003ctd\u003e4.57\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (ft)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003econfiguration_code\u003c\/td\u003e\n      \u003ctd\u003eQTC-ALFC4SSSSGEPTA100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Graco","offers":[{"title":"Default Title","offer_id":48980972372276,"sku":"TE30-0503","price":4680.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1483\/4824\/files\/Graco-TE30-0503_5bf148d6-a137-425f-a015-c00a2073d09c.jpg?v=1766174304","url":"https:\/\/hydrotechnologysystems.supply\/products\/graco-te30-0503-quantm-i30-1-npt-aluminum-electric-diaphragm-pump-240-vac-1ph-al-center-ss-seat-ss-ball-ge-diaphragm","provider":"HTS Supply LLC","version":"1.0","type":"link"}