{"product_id":"graco-te30-0215-quantm-i30-1-npt-aluminum-electric-diaphragm-pump-240-vac-1ph-al-center-ss-seat-fk-ball-fk-diaphragm","title":"Graco | TE30-0215 QUANTM i30, 1\"NPT, Aluminum Electric Diaphragm Pump, 240 VAC 1Ph, AL Center, SS Seat, FK Ball, FK Diaphragm","description":"\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eGraco\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eModel: TE30-0215\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe QUANTM electric pump offers reduced operational costs and enhanced reliability for production lines. Its innovative electric motor design and multiple fluid path options make it suitable for most fluid applications, serving as a dependable replacement for less efficient pneumatic pumps or for new installations. The unique self-priming, seal-less design provides consistent flow. It is the only electric diaphragm pump on the market that stalls under pressure, minimizing downtime from clogged lines or closed valves. The QUANTM is engineered for quieter operation, increased efficiency, and superior dependability, contributing to energy savings and sustainability goals. Consider converting to a QUANTM electric pump to optimize your pumping strategy and improve profitability.\u003c\/p\u003e\n\u003cp\u003eThe all-aluminum fluid section is designed for abrasion resistance and mild corrosion resistance. With up to 8 times more continuous torque at low speeds than conventional motors, this general-purpose electric pump is energy-efficient and suitable for sump evacuation, petroleum product evacuation (new and waste oils), and solvent evacuation. This pump enhances reliability to minimize downtime, and its plug-and-play design allows for easy integration into production lines without additional investment or infrastructure changes. Not intended for use with halogenated hydrocarbons.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevolutionary Design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eReplace existing air-operated pumps with electric pump technology that stalls under pressure and includes the AutoPrime feature.\u003c\/li\u003e\n\u003cli\u003eA compact and efficient electric drive eliminates the gearbox, offering a footprint comparable to a pneumatic diaphragm pump.\u003c\/li\u003e\n\u003cli\u003eAchieve up to an 80% reduction in energy consumption compared to pneumatic pumps, lowering operating costs and providing a rapid investment payback.\u003c\/li\u003e\n\u003cli\u003eQuiet operation reduces plant noise, improving employee safety and health.\u003c\/li\u003e\n\u003cli\u003eSmart pump control offers more precise flow set points and integrated I\/O capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Electric Motor\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePowder-coated aluminum electric drive.\u003c\/li\u003e\n\u003cli\u003e240 VAC 1Ph motor with a 15 ft cord and IEC 60320-C14 plug.\u003c\/li\u003e\n\u003cli\u003eNon-hazardous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials of Construction\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAluminum fluid section with NPT end port.\u003c\/li\u003e\n\u003cli\u003eInternal components include 316 stainless steel seat, FKM (Viton) ball, FKM (Viton) diaphragm, and PTFE manifold o-ring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e\n  .spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n    font-size: 15px;\n    box-shadow: 0 4px 12px rgba(0, 0, 0, 0.05);\n    border-radius: 8px; \/* Slightly rounded corners for a modern feel *\/\n    overflow: hidden; \/* Ensures border-radius clips the table *\/\n  }\n\n  .spec-table th,\n  .spec-table td {\n    padding: 14px 18px;\n    text-align: left;\n    border-bottom: 1px solid #eaeaea;\n  }\n\n  \/* Table Header *\/\n  .spec-table th {\n    background-color: #f9f9f9;\n    font-weight: 600;\n    letter-spacing: 0.5px;\n    color: #333;\n  }\n\n  \/* Table Body *\/\n  .spec-table tbody tr {\n    background-color: #ffffff;\n  }\n\n  \/* Zebra-striping for readability *\/\n  .spec-table tbody tr:nth-of-type(even) {\n    background-color: #fdfdfd;\n  }\n\n  \/* Subtle hover effect *\/\n  .spec-table tbody tr:hover {\n    background-color: #f5f5f5;\n  }\n\n  \/* Style the attribute name (first column) *\/\n  .spec-table td:first-child {\n    font-weight: 500;\n    color: #222;\n    width: 40%; \/* Give the label column a consistent width *\/\n  }\n\n  \/* Style the value (second column) *\/\n  .spec-table td:last-child {\n    color: #555;\n  }\n\n  \/* Remove bottom border from the last row for a cleaner look *\/\n  .spec-table tbody tr:last-child td {\n    border-bottom: none;\n  }\n\u003c\/style\u003e\n\n\n\u003ch4\u003eOperational Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUPC Product\u003c\/td\u003e\n      \u003ctd\u003e769946709728\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDivision\u003c\/td\u003e\n      \u003ctd\u003ePRO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeight\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLength\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWidth\u003c\/td\u003e\n      \u003ctd\u003e0 IN | 0.000 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVolume\u003c\/td\u003e\n      \u003ctd\u003e0 FT3 | 0.000 M3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e0 LBS | 0.000 KG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Amperage (A)\u003c\/td\u003e\n      \u003ctd\u003e10\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Flow Rate (L\/min)\u003c\/td\u003e\n      \u003ctd\u003e114\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (bar)\u003c\/td\u003e\n      \u003ctd\u003e6.9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (kPa)\u003c\/td\u003e\n      \u003ctd\u003e690\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (psi)\u003c\/td\u003e\n      \u003ctd\u003e100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (in)\u003c\/td\u003e\n      \u003ctd\u003e0.125\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e3.2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eQUANTM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Height (in)\u003c\/td\u003e\n      \u003ctd\u003e15.94\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003ei30\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e104\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e135\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e275\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Section\u003c\/td\u003e\n      \u003ctd\u003eAluminum, End Port, NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (m)\u003c\/td\u003e\n      \u003ctd\u003e4.57\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (ft)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (in)\u003c\/td\u003e\n      \u003ctd\u003e1\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003econfiguration_code\u003c\/td\u003e\n      \u003ctd\u003eQTC-ALFC2SSFKFKPTA100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Graco","offers":[{"title":"Default Title","offer_id":48980971815220,"sku":"TE30-0215","price":4807.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1483\/4824\/files\/Graco-TE30-0215_bca0e658-3c1d-4681-92f7-d95b42d3f728.jpg?v=1766174296","url":"https:\/\/hydrotechnologysystems.supply\/products\/graco-te30-0215-quantm-i30-1-npt-aluminum-electric-diaphragm-pump-240-vac-1ph-al-center-ss-seat-fk-ball-fk-diaphragm","provider":"HTS Supply LLC","version":"1.0","type":"link"}