{"product_id":"graco-te120-0192-quantm-i120-2-npt-aluminum-electric-diaphragm-pump-200-240-v-al-center-ge-seat-ge-ball-ge-diaphragm","title":"Graco | TE120-0192 QUANTM i120, 2\"NPT, Aluminum Electric Diaphragm Pump, 200-240 V, AL Center, GE Seat, GE Ball, GE Diaphragm","description":"\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eGraco\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eModel: TE120-0192\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe QUANTM electric pump offers a revolutionary electric motor design to reduce operational costs and ensure production line reliability. With multiple fluid path options and materials of construction, it is suitable for most fluid applications. It serves as a reliable drop-in replacement for less efficient pneumatic pumps or for new installations. Its self-priming, seal-less design provides smooth, steady flow. It is the only electric diaphragm pump on the market that stalls under pressure, reducing downtime from clogged lines or closed valves. The QUANTM is engineered for quieter operation, increased efficiency, and enhanced dependability, delivering energy savings that support sustainability goals. Consider converting to a QUANTM electric pump to optimize your pump strategy and improve profitability.\u003c\/p\u003e\n\u003cp\u003eThe all-aluminum fluid section is designed for abrasion resistance and mild corrosion resistance. This general-purpose electric pump provides up to 8x more continuous torque at low speeds than conventional motors, making it an energy-efficient solution for sump evacuation, petroleum product evacuation (new and waste oils), and solvent evacuation. This pump enhances reliability to minimize downtime. Its plug-and-play design allows for easy integration into production lines without additional investment or infrastructure changes. Not suitable for use with halogenated hydrocarbons.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevolutionary Design\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eReplace existing air-operated pumps with electric pump technology that stalls under pressure and includes the AutoPrime feature.\u003c\/li\u003e\n\u003cli\u003eA compact and efficient electric drive eliminates the gearbox, offering a footprint comparable to a pneumatic diaphragm pump.\u003c\/li\u003e\n\u003cli\u003eAchieve up to 80% reduction in energy consumption compared to pneumatic pumps, lowering operating costs and providing a quick investment payback.\u003c\/li\u003e\n\u003cli\u003eQuiet operation reduces plant noise and improves employee safety and health.\u003c\/li\u003e\n\u003cli\u003eSmart pump control offers more accurate flow set points and integrated I\/O.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Electric Motor\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003ePowder-coated aluminum electric drive.\u003c\/li\u003e\n\u003cli\u003e240 VAC 1Ph motor with 15 ft flying leads.\u003c\/li\u003e\n\u003cli\u003eATEX Ex II 2 G EX dh IIB T4 Gb hazardous location approval.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterials of Construction\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAluminum fluid section with NPT end port.\u003c\/li\u003e\n\u003cli\u003eInternal components include Geolast seat, Geolast ball, Geolast diaphragm, and PTFE manifold o-ring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e\n  .spec-table {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0;\n    font-family: -apple-system, BlinkMacSystemFont, \"Segoe UI\", Roboto, Helvetica, Arial, sans-serif;\n    font-size: 15px;\n    box-shadow: 0 4px 12px rgba(0, 0, 0, 0.05);\n    border-radius: 8px; \/* Slightly rounded corners for a modern feel *\/\n    overflow: hidden; \/* Ensures border-radius clips the table *\/\n  }\n\n  .spec-table th,\n  .spec-table td {\n    padding: 14px 18px;\n    text-align: left;\n    border-bottom: 1px solid #eaeaea;\n  }\n\n  \/* Table Header *\/\n  .spec-table th {\n    background-color: #f9f9f9;\n    font-weight: 600;\n    letter-spacing: 0.5px;\n    color: #333;\n  }\n\n  \/* Table Body *\/\n  .spec-table tbody tr {\n    background-color: #ffffff;\n  }\n\n  \/* Zebra-striping for readability *\/\n  .spec-table tbody tr:nth-of-type(even) {\n    background-color: #fdfdfd;\n  }\n\n  \/* Subtle hover effect *\/\n  .spec-table tbody tr:hover {\n    background-color: #f5f5f5;\n  }\n\n  \/* Style the attribute name (first column) *\/\n  .spec-table td:first-child {\n    font-weight: 500;\n    color: #222;\n    width: 40%; \/* Give the label column a consistent width *\/\n  }\n\n  \/* Style the value (second column) *\/\n  .spec-table td:last-child {\n    color: #555;\n  }\n\n  \/* Remove bottom border from the last row for a cleaner look *\/\n  .spec-table tbody tr:last-child td {\n    border-bottom: none;\n  }\n\u003c\/style\u003e\n\n\n\u003ch4\u003eOperational Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eUPC Product\u003c\/td\u003e\n      \u003ctd\u003e769946323856\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDivision\u003c\/td\u003e\n      \u003ctd\u003ePRO\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eHeight\u003c\/td\u003e\n      \u003ctd\u003e35.5 IN | 90.170 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eLength\u003c\/td\u003e\n      \u003ctd\u003e20 IN | 50.800 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWidth\u003c\/td\u003e\n      \u003ctd\u003e33 IN | 83.820 CM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eVolume\u003c\/td\u003e\n      \u003ctd\u003e13.543 FT3 | 0.383 M3\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eShipping Weight\u003c\/td\u003e\n      \u003ctd\u003e135 LBS | 61.235 KG\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\n\u003ch4\u003eTechnical Specifications\u003c\/h4\u003e\n\u003ctable class=\"spec-table\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n            \u003cth\u003eValue\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (in)\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e51\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Inlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e50.8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Outlet Thread Gender\u003c\/td\u003e\n      \u003ctd\u003eFemale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Amperage (A)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Flow Rate (L\/min)\u003c\/td\u003e\n      \u003ctd\u003e454\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (bar)\u003c\/td\u003e\n      \u003ctd\u003e4.14\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (kPa)\u003c\/td\u003e\n      \u003ctd\u003e414\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Pressure (psi)\u003c\/td\u003e\n      \u003ctd\u003e60\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (in)\u003c\/td\u003e\n      \u003ctd\u003e0.25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Solid Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e6.4\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eModel\u003c\/td\u003e\n      \u003ctd\u003eQUANTM\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOverall Height (in)\u003c\/td\u003e\n      \u003ctd\u003e23.6\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eSeries\u003c\/td\u003e\n      \u003ctd\u003ei120\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e104\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e82\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e180\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMinimum Fluid Operating Temperature (°F)\u003c\/td\u003e\n      \u003ctd\u003e-40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Section\u003c\/td\u003e\n      \u003ctd\u003eAluminum, End Port, NPT\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eMaximum Ambient Temperature (°C)\u003c\/td\u003e\n      \u003ctd\u003e40\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (m)\u003c\/td\u003e\n      \u003ctd\u003e4.57\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCord Length (ft)\u003c\/td\u003e\n      \u003ctd\u003e15\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (in)\u003c\/td\u003e\n      \u003ctd\u003e2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eFluid Passage Size (mm)\u003c\/td\u003e\n      \u003ctd\u003e51\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003econfiguration_code\u003c\/td\u003e\n      \u003ctd\u003eQTE-ALFC4GEGEGEPTA100\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight (kg)\u003c\/td\u003e\n      \u003ctd\u003e44.9\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Graco","offers":[{"title":"Default Title","offer_id":48980931019060,"sku":"TE120-0192","price":5807.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1483\/4824\/files\/Graco-TE120-0192_0148e79a-20c0-4b1a-80b9-4619fe6448b3.jpg?v=1766173335","url":"https:\/\/hydrotechnologysystems.supply\/products\/graco-te120-0192-quantm-i120-2-npt-aluminum-electric-diaphragm-pump-200-240-v-al-center-ge-seat-ge-ball-ge-diaphragm","provider":"HTS Supply LLC","version":"1.0","type":"link"}